TM-10-4930-247-13-P

HEMTT TANKER AIRCRAFT REFUELING SYSTEM MODEL HTARS100

TECHNICAL MANUAL; OPERATOR’S, UNIT AND DIRECT SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

FEBRUARY 1994

  TM-10-4930-247-13-P - Page 63 of 309

TM 10-4930-247-13&P
2-12.
OPERATING PROCEDURES - cont.
e.
Open Port Nozzle Operation.
Refer to figure 2-15.
The open port nozzle must be connected to the CCR nozzle
prior to operation.
The CCR nozzle reduces system fuel pressure to the open port nozzle to prevent excessive
fuel flow to the aircraft.
(1)
Remove dust cover (1) from end of discharge tube (2).
(2)
Place end of discharge tube (2) in fuel tank adapter (3).
(3)
Set CCR Nozzle (4) to OPEN.
Refer to TM
10-4930-248-13&P.
(4)
Squeeze control handle (5) to dispense fuel.
(5)
When fuel tank is full, release control handle (5).
(6)
Remove end of discharge tube (2) from fuel tank adapter (3).
(7)
Set CCR nozzle (4) to CLOSE.
Refer to TM
10-4930-248-13&P.
(8)
Install dust cover (1) on end of discharge tube (2).
Figure
2-15.
Open Port Nozzle Operation.
Change 6
2-37


Back to Top