TM 5-2330-378-14&P
4-79. DATA PLATEREPLACEMENT(M870)(continued).
3.
Drill out drive screw holes (4).
WARNING
Drycleaning solvent is toxic and flammable. Always wear protective goggles and
gloves and use only In a well-ventilated area. Avoid contact with eyes, skin, and
clothes and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
4.
If data plate (2) is attached with adhesive, scrape it off frame (3) with putty knife. Thoroughly
clean frame with
drycleaning
solvent and rag.
3
3
4
2
2
0
1
b.
INSTALLATION
NOTE
If replacing
adhesive
attached
plate,
do
step
1 only.
For
plate
attached
with
drive
screws, do step 2 only.
1 .
Peel protective backing from data plate (2) and apply to frame (3) at location of old data plate.
2.
Place data plate (2) in position on frame (3) and secure with four drive screws (1).
FOLLOW-ONTASKS:
- None
4-166