3-24
TM 5-2350-262-20-3
NO
NO
YES
from block 7
To block 12
YES
YES
9
Check hydraulic pressure at port 13R.
Is pressure 3,950-4,050 psi (27,235-27,925 kPa)?
1
ALL HYDRAULIC FUNCTIONS INOPERATIVE (CONTINUED)
10
Perform 13R main relief valve adjustment.
Can hydraulic pressure be adjusted
3,950-4050 psi (27,235-27,925kPa?
11
Remove all test equipment and connect hoses.
Replace directional control valve bank.