TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 56 of 319

3-21
TM 5-2350-262-20-3
MAIN PUMP SUCTION HOSE CHECK
WARNING
Do not work under vehicle unless hull has been properly blocked
or allowed to settle on bump stops.
Failure to comply may result
in severe injury or death to personnel.
NOTE
Have suitable container ready to catch oil.
Loosen, but do not disconnect, PUMP SUCT TUBE-7 (1) from elbow (2) on main hydraulic
pump (3).
Hydraulic oil should flow freely from the loosened fitting.


Back to Top