TERMINAL-TYPE CABLE CONNECTORS REPLACEMENT
1.
Strip cable insulation equal to depth of terminal wall (Figure 3).
2.
Slide insulator over cable (Figure 3).
3.
Insert cable into terminal well and crimp (Figure 3).
4.
Slide insulator over crimped end of terminal (Figure 3).
M0119HBF
TERMINAL
INSULATOR
CABLE
Figure 3.
Terminal-type Cable Connector.
END OF TASK
MALE CABLE CONNECTOR REPLACEMENT
1.
Strip cable insulation equal to depth of ferrule well (Figure 4).
2.
Slide shell over cable and remove C-washer (Figure 4).
3.
Insert cable into ferrule and crimp (Figure 4).
4.
Place C-washer over cable at crimped junction and slide shell over C-washer and ferrule (Figure 4).
M0120HBF
TERMINAL
C-WASHER
SHELL
CABLE
Figure 4.
Male Cable Connector.
END OF TASK
TM 5-2350-377-13&P
0049
0049-4