DISASSEMBLY
CAUTION
•
Disassembly should be performed in a clean environment and protective dust covers or
caps should be installed on all openings to prevent contamination. Dirt can damage parts
and cause malfunctions.
•
When securing forward right manifold in vise, exercise extreme care not to mar any
surfaces or damage components.
1.
Remove two adapters (Figure 2, Item 3), two O-rings (Figure 2, Item 2), two adapters (Figure 2, Item 10), two
O-rings (Figure 2, Item 7), adapter (Figure 2, Item 11), O-ring (Figure 2, Item 4), adapter (Figure 2, Item 8),
O-ring (Figure 2, Item 7), adapter (Figure 2, Item 5), O-ring (Figure 2, Item 4), adapter (Figure 2, Item 6), and
O-ring (Figure 2, Item 7) from right manifold (Figure 2, Item 9). Discard O-rings.
2.
Remove two two-way (NO) valves V2 and V10 (Figure 2, Item 12), two packing retainers (Figure 2, Item 14),
two O-rings (Figure 2, Item 15), two packing retainers (Figure 2, Item 14), two O-rings (Figure 2, Item 13),
transducer T11 (Figure 2, Item 1), and O-ring (Figure 2, Item 2) from right manifold (Figure 2, Item 9). Discard
O-rings and packing retainers.
4
5
6
8
7
7
9
7
10
4
11
7
10
14
15
14
13
14
15
14
13
12
1
2
2
2
3
M0029HDC
Figure 2.
Hydraulic Diagnostic Center (HDC) Forward Right Manifold Disassembly.
END OF TASK