TM 5--2350--378--24&P
0008 00--8
APRON, BILGE PUMP, AND LEFT--HAND WHEEL CONTROL INOPERATIVE -- Continued
0008 00
YES
Perform 13R main relief valve adjustment.
Can the 13R main relief valve be set to
develop hydraulic pressure between
3,950--4,050 psi (27,235--27,925 kPa)?
Verify transducer T--3 hydraulic
pressure is between 3,950--4,050
psi (27,235--27,925 kPa).
NO
3
2
To Block 5
Verify problem is solved.
NO
from block 1