TM 5--2350--378--24&P
0009 00--1
APRON WILL NOT RAISE
0009 00
INITIAL SETUP:
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0071 00, item 7)
Personnel Required
Two 62B10
References
TM 5--2350--262--20--2
WP 0035 00
Equipment Conditions
Vehicle MASTER power OFF (TM 5--2350--262--10)
Vehicle on jack stands (TM 5--2350--262--20--1)
The apron cylinders receive oil flow from main control valve circuits 19 and 20. Relief valves at ports 19 and 20 of
main control valve limit pressure to apron cylinders to 3,500 psi (24,131 kPa).
WARNING
High oil pressure is present in the M9 hydraulic system. Do not disconnect any
hydraulic system component unless hydraulic system pressure has been relieved.
After hydraulic system pressure has been relieved, wait at least 4 minutes before
disconnecting any hose or fitting. Ensure each of the hydraulic control levers is
moved several times through all positions and the hydraulic tank dipstick is slowly
loosened to relieve pressure. Failure to comply may result in severe injury or death
to personnel.