TM 5--2350--378--24&P
0008 00--10
APRON, BILGE PUMP, AND LEFT--HAND WHEEL CONTROL INOPERATIVE -- Continued
0008 00
NO
6
NO
from block 2
YES
5
Perform main hydraulic pump pressure
test using the HDC.
Does pressure transducer T--3 indicate main
hydraulic pump developes 3,950--4,050 psi
27,235--27,925 kPa)?
7
Notify Direct Support maintenance to
replace main hydraulic pump.
Replace directional control valve bank
(TM 5--2350--262--20--2).