TM 5--2350--378--24&P
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
Figure 28. HDC Control Box
SUSPENSION RAISE/LOWER RELIEF VALVE TEST
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 28,
item 5) on the HDC control box.
NOTE
This test is done at both right--hand and left--hand suspension
raise/lower relief valves. For the right--hand valve (port 3R),
actuate the right--hand SUSPENSION CONTROL lever. For the
left--hand valve (port 3L), actuate the left--hand SUSPENSION
CONTROL lever.
For 3R; using LINE UP or LINE DOWN button (Figure 28, item 3), select V15 on the
HDC display (Figure 28, item 2). Close V15 on the HDC display (Figure 28, item 2) by
selecting the CHANGE POSITION button (Figure 28, item 4) on the HDC control box.
Have assistant start engine. Move right--hand SUSPENSION CONTROL lever to
RAISE. Read transducer T--1 hydraulic pressure on the HDC display (Figure 28,
item 1).
Using LINE UP or LINE DOWN button (Figure 28, item 3), select V15 on the HDC
display (Figure 28, item 2). Open V15 on the HDC display (Figure 28, item 2) by
selecting the CHANGE POSITION button (Figure 28, item 4) on the HDC control box.
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 28,
item 5) on the HDC control box.
For 3L; using LINE UP or LINE DOWN button (Figure 28, item 3), select V16 on the
HDC display (Figure 28, item 2). Close V16 on the HDC display (Figure 28, item 2) by
selecting the CHANGE POSITION button (Figure 28, item 4) on the HDC control box.
Continued on page 0016 00--41.
0016 00--39/40 blank