TM 5--2350--378--24&P
0016 00--42
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
To block 29
To block 28
27
Perform suspension raise/lower relief valve adjustment
using the HDC.
NO
YES
Observe transducer T--1 hydraulic pressure. Can
pressure at suspension raise/lower relief valves be
adjusted to 3,450--3,550 psi (23,788--24,477 kPa)?
NO
from block 26