0016 00--75
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
Figure 53. HDC Control Box
SUSPENSION RELIEF VALVE PRESSURE TEST
WARNING
Before performing any hydraulic troubleshooting in bowl, move
ejector forward and engage the ejector lock. Failure to comply may
result in severe injury or death to personnel.
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 53,
item 5) on the HDC control box.
Start engine; move ejector forward, engage ejector lock.
Stop engine and relieve hydraulic pressure.
Using LINE UP or LINE DOWN button (Figure 53, item 3) on the HDC control box,
select V5 on the HDC display (Figure 53, item 2). Using the CHANGE POSITION
button (Figure 53, item 4), close V5 on the HDC display (Figure 53, item 2). Repeat
steps and close V12 and V13, and open V19.
Have assistant start engine and move SPRUNG/UNSPRUNG lever to UNSPRUNG and
right--hand SUSPENSION CONTROL lever to LOWER. Read transducer T--13
hydraulic pressure on the HDC display (Figure 53, item 1).
Using LINE UP or LINE DOWN button (Figure 53, item 3) on the HDC control box,
select V5 on the HDC display (Figure 53, item 2). Using the CHANGE POSITION
button (Figure 53, item 4), open V5 on the HDC display (Figure 53, item 2). Repeat
steps and open V12 and V13, and close V19.