TM 5--2350--378--24&P
0016 00--67
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
Figure 49. Main Hydraulic Accumulator
MAIN HYDRAULIC ACCUMULATOR PRESSURE TEST
WARNING
S
High--pressure nitrogen gas is used in this equipment. Keep hands
and face away from valves and hose ends. Failure to comply may
result in severe injury or death to personnel.
S
Do not breathe nitrogen gas. Failure to comply may result in severe
injury or death to personnel.
Connect pressure measuring device (Figure 49, item 4) to bleed valve (Figure 49,
item 10) on charging harness (Figure 49, item 12). Close shutoff valve (Figure 49,
item 3).
Open nitrogen tank valve (Figure 49, item 1) and adjust regulator valve (Figure 49,
item 2) to 50 psi (353 kPa).
Open shutoff valve (Figure 49, item 3) for about 10 seconds to clear charging hoses.
Close valve (Figure 49, item 3).
Remove valve guard (Figure 49, item 11). Remove charge valve cap (Figure 49, item 8)
from charge valve assembly (Figure 49, item 6) on accumulator (Figure 49, item 9).
Loosely connect adapter valve (Figure 49, item 5) to charge valve (Figure 49, item 6)
and again open shutoff valve (Figure 49, item 3) for about 10 seconds. Close shutoff
valve (Figure 49, item 3). Fully tighten adapter valve (Figure 49, item 5).
NOTE
Accumulator gas valve is fully open after about 2--1/2 turns.
Open charge valve (Figure 49, item 6) by loosening nut (Figure 49, item 7). Read
pressure measuring device (Figure 49, item 4).