TM 5--2350--378--24&P
0016 00--63
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
Figure 47. Apron Control Valve
APRON RELIEF VALVE PRESSURE TEST
WARNING
Before performing any hydraulic troubleshooting in bowl, move
ejector forward and engage the ejector lock. Failure to comply may
result in severe injury or death to personnel.
NOTE
Have suitable container ready to catch oil.
Start engine, move ejector forward, engage ejector lock.
Stop engine; relieve hydraulic pressure.
Disconnect CONT VLV--20 hose (Figure 47, item 5) from elbow (Figure 47, item 1) at
port 20 of apron control valve. Connect pressure measuring device (Figure 47, item 2)
to elbow (Figure 47, item 1). Plug hose (Figure 47, item 5).
Have assistant start engine and hold APRON CONTROL lever in DOWN position. Read
pressure measuring device (Figure 47, item 2).
APRON RELIEF VALVE ADJUSTMENT
As assistant holds APRON CONTROL lever DOWN, loosen jam nut (Figure 47, item 3)
and rotate adjusting screw (Figure 47, item 4) clockwise to increase pressure;
counterclockwise to decrease pressure. When adjustment is completed, tighten jam nut
(Figure 47, item 3).
Stop engine; relieve hydraulic pressure.