TM 5--2350--378--24&P
0016 00--61
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
APRON RELIEF VALVE ADJUSTMENT -- CONTINUED
Disable ejector; manually close V23 (Figure 45, item 1) on the DCV bank. Using LINE
UP or LINE DOWN button (Figure 44, item 3), select V1 on the HDC display (Figure 44,
item 2). Close V1 on the HDC display (Figure 44, item 2) by selecting the CHANGE
POSITION button (Figure 44, item 4) on the HDC control box.
Using LINE UP or LINE DOWN button (Figure 44, item 3), select V17 on the HDC
display (Figure 44, item 2). Close V17 on the HDC display (Figure 44, item 2) by
selecting the CHANGE POSITION button (Figure 44, item 4) on the HDC control box.
Start engine.
As assistant holds APRON CONTROL lever in the UP position, loosen jam nut
(Figure 46, item 1) while observing transducer T--1 hydraulic pressure on the HDC
display (Figure 44, item 1).
Rotate adjusting screw (Figure 46, item 2) clockwise to increase pressure; counter--
clockwise to decrease pressure, as necessary to obtain desired pressure. Tighten jam
nut (Figure 46, item 1).
Stop engine; relieve hydraulic pressure.
Manually open V23 (Figure 45, item 1) on the DCV bank. Using LINE UP or LINE
DOWN button (Figure 44, item 3), select V1 on the HDC display (Figure 44, item 2).
Open V1 on the HDC display (Figure 44, item 2) by selecting the CHANGE POSITION
button (Figure 44, item 4) on the HDC control box. Using LINE UP or LINE DOWN
button (Figure 44, item 3), select V17 on the HDC display (Figure 44, item 2). Open
V17 on the HDC display (Figure 44, item 2) by selecting the CHANGE POSITION button
(Figure 44, item 4) on the HDC control box.
Figure 44. HDC Control Box
Figure 45. DCV Bank
Figure 46. Apron Relief Valve