TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 369 of 790

TM 5--2350--378--24&P
0016 00--66
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
NO
from block 44
To block 47
YES
from block 9
YES
NO
46
Is gas valve pressure 1,750--1,850 psi
(12,066--12,756 kPa)?
Perform main accumulator pressure test.
To block 48