TM 5--2350--378--24&P
0016 00--62
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
YES
from block 36
Stop engine, relieve hydraulic
pressure.
42
Remove all test equipment and connect lines.
Verify problem is solved.
YES
NO
YES
NO
40
41
Perform apron relief valve adjustment.
43
Perform apron relief valve (port 20) pressure test.
Is pressure 3,450--3,550 psi (23,780--24,475 kPa)?
Can pressure be adjusted to 3,450--3,550 psi
(23,780--24,475 kPa)?
To block 44
Replace directional control valve bank
(TM 5--2350--262--20--2).