TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 471 of 790

TM 5--2350--378--24&P
0021 00--8
WINCH WILL NOT PULL RATED LOAD -- Continued
0021 00
4
Replace directional control valve
bank assembly (TM 5--2350--262--20--2).
2
Can relief valve be set to develop the correct hydraulic pressure:
1,950--2,050 psi (13,445--14,135 kPa)?
NO
from block 1
3
Verify problem is solved.
YES
Perform winch relief valve VB adjustment using the HDC.
NO