TM 5--2350--378--24&P
APPARENT HDC SYSTEM PROBLEM -- Continued
0022 00
YES
NO
from block 50
56
Is the “CIRCUIT FAULT” component that did not
pass the functional test a solenoid valve?
NO
NO
NO
57
Replace the HDC system component (the
original solenoid valve or pressure transducer)
that did not pass the functional test the first time.
55
Repeat the functional test of the HDC system
components that originally did not pass the functional
check--out (now using an identical spare component in
its place).
Change out the HDC system component that did not
pass the functional check--out with an identical, known
good spare, component (solenoid valve or pressure
transducer, as applicable) or temporarily switch
identical type components from another nearby
location in the HDC system.
Did the functional check--out test fail again for the
same component designator as it did for the original
component in the previous test?
YES
58
Solenoid valve.
59
Pressure transducer.
To block 63
To block 73
NO
Power off HDC system.
0022 00--30/31 blank