APPARENT HDC SYSTEM PROBLEM -- Continued
0022 00
YES
NO
from block 66
NO
NO
69
Substitute a spare (good) solenoid valve with the
“CIRCUIT FAULT” solenoid valve and repeat the test.
68
Perform continuity test and check for short
circuit to cable (connector case/shell) for the
two pins/wires in the W4 cable that go from
connector W4P2 or W4P3 (as applicable),
normally connected to the HDC control box, to
the W4P5 or W4P6 connector (as applicable)
normally connected to the umbilical disconnect
bracket.
Disconnect umbilical cable W4 connector W4P2
on W4P3 (from HDC control box connector J2 or
J3, as applicable) associated with designated
“CIRCUIT FAULT” solenoid valve.
Does an open circuit or short circuit exist in the
umbilical cable assembly W4 wiring circuit
(”CIRCUIT FAULT” solenoid valve 28 VDC
energizing circuit) being checked?
YES
NO
70
Replace HDC control box.
71
Replace the original “CIRCUIT
FAULT” solenoid identified by the BIT
valve (WP 0031 00, WP 0032 00,
WP 0033 00, WP 0034 00).
Are the results the same?
Resume the HDC system
functional check--out.
72
Replace umbilical cable assembly W4.
Resume the HDC system functional
check--out.