TM 5--2350--378--24&P
APPARENT HDC SYSTEM PROBLEM -- Continued
0022 00
YES
YES
from block 61 or
block 58
NO
NO
63
If here, “CIRCUIT FAULT” message is associated
with a solenoid valve (lower LCD screen display).
Power off HDC system.
Tag the W2 or W3 cable assembly electrical lead to
the HDC system solenoid valve (on the HDC
system primary manifold, right forward manifold,
left forward manifold, or aft manifold, as applicable)
identified in the “CIRCUIT FAULT” message and
switch electrical leads with another (identical type)
solenoid valve on the same manifold assembly.
Power up HDC system again.
Does lower LCD screen display the same
“CIRCUIT FAULT” message (identifying the same
solenoid valve as the previous “CIRCUIT FAULT”
message)?
65
Power off HDC system.
Replace the applicable HDC system solenoid
valve identified in the first “CIRCUIT FAULT”
message (WP 0031 00, WP 0032 00,
WP 0033 00, WP 0035 00).
If a “good” solenoid valve was switched with
another valve to check out the first valve, make
sure the good valve is returned to its original
location.
Reconnect proper electrical leads and ensure all
W2 or W3 electrical leads are mated with the
proper solenoid valves.
Continue performing HDC system functional
check--out.
64
Power off HDC system.
If a “good” solenoid valve was switched with
another valve to check out the first valve, make
sure the good valve is returned to the original
location.
Reconnect proper electrical leads and ensure all
W2 or W3 electrical leads are mated with the
proper solenoid valves.
YES
To block 66
0022 00--34/35 blank