f.
If ampere output is within 10 percent of
rated output as stamped on generator
frame, integral charging system is not
defective.
In this case, an adjustment of
the voltage setting may correct the
undercharged condition.
Raise the setting
by removing the voltage adjusting cap,
rotating in increments of 90° and then
reinserting the cap in the connector body.
As illustrated in Fig.
4, the cap is set for
medium high voltage.
With position 2
aligned with the arrow, the setting is
medium low; position "LO" is low, and
position "HI" is the highest regulator setting.
After adjusting the setting, check for an
improved energizer condition after a service
period of reasonable length, such as one