TRUCK SERVICE MANUAL
FUEL SYSTEM
Complaints And Corrections
Charted on the following pages are the complaints,
showing the items to check for correction of the
complaints.
Each check is numbered, and the item
numbers from Fig.
61121 are given for quick location, so
you may go immediately to the tabulated description of
the causes and corrective action as necessary.
Check 1-Vials
Cause
Differential of 1 cc or more between the vials.
Metered fuel partially missing vials.
Foam preventing accurate reading of fuel delivery in
vials.
Correction
Remove the vials and check the relative accuracy by
filling one to various levels and pouring into the other vial.
If there is significant variation between the two vials,
mark the vials (spot of paint on one) and record the
relative variation for future reference in troubleshooting.
If the differential is significant at 132 cc, choose one vial
(the one marked with a spot of paint above) for machine
calibration use and when trouble-shooting the machine.
Replace with correctly calibrated vials as soon as
possible.
Adjust solenoid outlet line so that 100% of the metered
fuel enters the vials.
(For minimum fuel foam, direct
stream of fuel against side of vial.)
Foam will settle in approximately one minute.
To prevent
this time loss a 1" diameter hole may be cut in the top
panel (with panel removed) and the foam may be stirred
with a wire or rod.
483