TM-5-3805-254-20-2

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 2 OF 2

JANUARY 1988

  TM-5-3805-254-20-2 - Page 21 of 971

TM 5-3805-254.20-2
GENERATOR AND REGULATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ADJUSTMENT
NOTE
Adjust generator if ampere output is not within 10 percent of rated output stamped on generator.
Go to Troubleshooting (page 2-43).
17.
Connector body (1)
Voltage adjustment
a.
Take out.
cap (2)
b.
Rotate 90-degrees clockwise to raise
ampere output, and counterclockwise to
lower ampere output.
c.
Put in.
NOTE
FOLLOW-ON MAINTENANCE:
1.
Connect battery ground cable (page 2424).
2.
Close right side hood panel (page 2-424).
TASK ENDS HERE
TA244130
2-670


Back to Top