TM 5-3805-254-20-2
GENERATOR PULLEY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
2.
Armature (1)
Generator pulley (2)
Using mechanical puller, pull off.
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable.
Wear protective safety goggles and gloves
and use only in a well-ventilated area.
Avoid contact with skin, eyes, and clothes and do not
breathe vapors.
Do not use near open flame or excessive heat.
The flashpoint for type #1
drycleaning solvent is 100
°
F (38
°
C) and for type #2 is 138°F (59
°
C).
If you become dizzy while
using cleaning solvent, get fresh air immediately, and get medical aid.
If contact with eyes is
made, flush your eyes with water and get medical aid immediately.
NOTE
Parts must be cleaned thoroughly.
For more information on how to clean parts, go to General
Maintenance Instructions (page 2-424).
3.
All parts
Using drycleaning solvent, clean
thoroughly.
WARNING
Particles blown by compressed air are hazardous.
Make certain the air stream is directed away
from user and other personnel in the area.
Compressed air used for cleaning purposes shall not
exceed 30 psi (207 kPa).
User must wear safety goggles or face shield to prevent injury to
personnel.
4.
All parts
Using air blow gun and air hose assembly,
blow dry.
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to
General Maintenance Instructions (page 2-424).
2-672