(9)
Using seal plate assembly (14, fig. 3-56) and a new seal (13) fill the cavity between seal
lips half full with multi-purpose grease. Position seal (13), plate (14), and gasket (12) on housing, being
cautious not to damage the lip seal. Install upper two capscrews (16) and lockwashers (15). Torque to
11 lb-ft (15 N
.
m).
NOTE
To check plunger action, introduce compressed air to
internal feed port. Actuate valve spool (7, fig. 3-10)
forward and backward from detented position to con-
firm free travel to plunger assembly (30).
(10)
Place a new gasket (9) on pump (or motor) housing using a thin coat of clean tran-
mission oil to hold it in place.
Figure 3-56. Control Valve Spool with Cam Follower.