TM-5-3895-371-24-P

BITUMINOUS DISTRIBUTOR BODY M918, MODEL D-63

TECHNICAL MANUAL; ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST

MARCH 1981

  TM-5-3895-371-24-P - Page 22 of 330

TM 5-3895-371-24 & P
e. Nozzles.
Type:
Thread:
Slot:
Spacing :
f.
Bituminous Pump Data.
Make:
Model:
Operating Pressure:
Output Capacity:
g. Burner System.
Fuel Consumption (Maximum) :
Fuel Consumption (Minimum):
Each Burner:
h. Capacities.
Fuel Tank, Burner:
Material Storage Tank:
Portable Burner Tank:
Hydraulic Reservoir:
Fan
1/2 inch national pipe thread
1/8 inch (.32 cm)
4 inch (10.16 cm)
ED. Etnyre & Co., Inc.
P 15T
20 pounds per square inch (6.89 kPa)
400 gallons (1514 l) per minute
12 gallons (45.42 I) per hour
1-1/2 gallons (5.68 I) per hour
3/4 gallons (2.84 I) per hour
36 gallons (136.26 I)
1500 gallons (5677.5 I)
4 gallons (15.14 I)
20 gallons (75.7 I)
1-7/1-8 (Blank)