ADMIX SYSTEMS.
6-8.
STRAINER SERVICE (Continued).
LOCATION/ITEM
ACTION
REMARKS
A.
REMOVAL.
NOTE
Each liquid admix system has a strainer screen. The procedure below may be used to clean the hi-flow or
the low-flow strainer.
NOTE
Close solution gate valve adjacent to strainer, if tank is full.
1. Draincock (5).
Open.
2. Draincock (5) and
Remove.
bushing (4).
3. Cap (3).
Unscrew and remove.
Use a six point socket.
Remove screen (2).
B.
CLEANING AND INSPECTION.
4. Screen (2).
a.
Clean. Use cleaning agent
recommended by admixture
manufacturer.
Then use water.
b.
Inspect for:
Replace if necessary.
(1)
Cracks
(2)
Breaks
(3)
Deformities.
5. Housing (1).
Wash out any sediment.
C. INSTALLATION.
6. Screen (2).
Place in housing (1).
7. Cap (3).
Screw on and tighten.
Use a six point socket
8. Draincock (5) and
Install bushing (4).
9. Draincock (5).
Close.