TM 5-3895-372-20
Table 6-1.
Admix Systems Troubleshooting Procedures (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
LIQUID ADMIX FLOWS TOO SLOWLY OR NOT AT ALL (Continued):
Step 7.
Check mechanical linkage between quick acting valve and main clutch lever.
Valve should be opened fully when clutch is engaged.
Repair linkage.
Check for broken down pipe or clogged breather in pipe.
Step 8.
Beginning at nozzles and working back to tanks, check individual components
for blockage.
Be sure to check down pipes in tanks for blocked breather holes.
Clean or replace blocked lines or valves (para 6-14).
TA 076245