TM 5-3895-372-20
Table 6-1.
Admix Systems Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
AIR PRESSURE CANNOT BE MAINTAINED AT 15 PSI (103 kPa):
Step 1.
Check for open draincocks and vents.
Close all draincocks and vents.
Step 2.
Use soap solution to check for air leaks.
Tighten loose fittings.
Replace leaking valves or lines (para 6-14).
Step 3.
Turn regulator in both directions.
Watch gage for pressure response.
Replace faulty regulator (para 6-14).
Step 4.
Attach pressure gage between regulator and gate valves.
Check that it reads the
same as pressure gage installed on regulator.
Replace pressure gage (pare 6-14).
Step 5.
Increase pressure to 18-20 psi (124-138 kPa).Check that relief valves vent when
pressure reaches 18-20 psi (124-138 kPa).
Adjust relief valve (para 6-17).
Step 6.
Check for blockage in supply line.
Remove obstruction or replace line (para 6=14).
Step 7.
Check compressed air system for leaks.
Troubleshoot compressed air system (para 11-5).
2.
LIQUID ADMIX FLOWS UNEVENLY:
Step 1.
Check for 14½ - 15'
psi (100-107 kPa) air pressure.
See Malfunction No.
1.
Step 2.
Check for leaks.
Tighten loose connections.
Replace leaking lines or valves (para 6-14).
Step 3.
Check for dirt or sediment in system.
Flush system.
First use cleaning agent recommended by admixture manufacturer.
Then use clean water.
6-3