TM 5-3895-372-20
Table 8-1.
Cement System Troubleshooting Procedures (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7.
CEMENT SCREEN DOES NOT VIBRATE (Continued):
Step 3.
Check that chassis air pressure is over 65 psi (448 kPa).
Start up truck and allow pressure to build up.
If pressure remains low, trouble-
shoot chassis air system (see TM 9-2320-273-20).
Step 4.
Check for air leaks.
Tighten connections or replace leaking part (para 11-12).
Step 5.
Check air supply at vibrator.
Find blocked line or valve.
Remove block or replace part (para 11-12).
Step 6.
Replace vibrator (para 11-8).
8-15