TM 5-4210-249-13&P-1
0120-9
DRAFT
0120
TFFT03536
Step 11.
Put GROUND SWEEPS switch to off position (WP 0004).
Turn battery disconnect
switch to OFF position (WP 0007).
Remove skid plate grille (WP 0550).
Disconnect
main wire harness main 5 connector.
With a test lead set, check for continuity across
main wire harness wire 2772 (gray) from main 5 connector, terminal 13 to main wire
harness valve control wire harness connector DV1, terminal 10.
a.
If there is continuity, repair wire 2772 in cab pump control wire harness
if repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
b.
If there is no continuity, repair wire 2772 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top