TM 5-4210-249-13&P-1
0121-2
DRAFT
0121
TFFT04320
Step 1.
Turn battery disconnect switch to ON position (WP 0007).
Start vehicle
engine (TM 9-2320-347-10).
While an assistant puts cab GENERATOR PTO switch to
on position (WP 0004), check if 200 to 240 VAC are displayed on hydraulic generator
digital display module AC volts display.
If 200 to 240 VAC are displayed and GEN PTO indicator is not illuminated,
troubleshoot GEN PTO ENGAGE Indicator Does Not Illuminate
(Cab) (WP 0139).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION