TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 1075 of 1188

TM 5-4210-249-13&P-1
0120-13
DRAFT
0120
TFFT03540
Step 15.
Install circuit breaker 11 (WP 0398).
Disconnect cab power distribution wire harness
cab pump control wire harness connector.
With a test lead set, check for continuity
across cab pump control wire harness wire 2854 (red) from cab pump control wire
harness GROUND SWEEPS switch connector, terminal 5 to cab pump control wire
harness connector, terminal 1.
a.
If there is continuity, repair wire 2854 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
b.
If there is no continuity, repair wire 2854 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump
control wire harness (WP 0443).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top