TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 1080 of 1188

TM 5-4210-249-13&P-1
0121-4
DRAFT
0121
TFFT03739
WARNING
ICON 15
PTO solenoid operation is checked by listening to audible click and feeling for
vibrations at PTO solenoid when PTO switch is put to on position (WP 0004).
Do
not start engine during this procedure.
Failure to comply may result in serious
injury or death to personnel.
Step 4.
Turn battery disconnect switch to OFF position (WP 0007).
Remove PTO pump
(WP 0601).
Turn battery disconnect switch to ON position (WP 0007).
Start vehicle
engine (TM 9-2320-347-10).
While an assistant puts GENERATOR PTO switch to on
position (WP 0004), check if hydraulic generator PTO drive rotates.
a.
If hydraulic generator PTO drive rotates, replace PTO pump
(WP 0601).
b.
If hydraulic generator PTO drive does not rotate, replace PTO
(WP 0600).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top