FIELD LEVEL MAINTENANCE
HIGH PRESSURE WATER SOURCE INTAKE RELIEF VALVE SETTING
INITIAL SETUP:
ADJUSTMENT
NOTE
If water pressure is too high, intake relief valve may need to be adjusted.
After mission is
complete, reset intake relief valve setting to 125 psi (862 kPa).
1.
Loosen, but do not remove jamnut (1) on stem (2).
2.
Loosen, but do not remove stem (2) on valve (3).
Relief pressure is now set at 50 psi (345 kPa).
3.
Carefully tighten stem (2) until resistance is felt.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00320
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
References
WP 0615, Fig. 37
Equipment Conditions
Water pump engine OFF (WP 0022)
Engine off (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)