CAUTION
Prior to adjustment, ensure generator system is unloaded and hydraulic pump is
within rpm operating parameters.
Failure to comply may cause damage to
equipment.
3.
Unload generator system (WP 0021).
4.
Remove cap (2) from hydraulic compensator (3).
5.
Loosen jamnut (4).
6.
Holding jamnut (4), adjust adjusting screw (5) to proper setting.
7.
Holding adjusting screw (5), tighten jamnut (4).
8.
Install cap (2) from hydraulic compensator (3).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE