TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 891 of 1452

TM 5-4210-249-13&P-2
0193-3
DRAFT
0193
NOTE
Adjustments to pressure governor controls should be made in small increments.
Note value of GAIN.
4.
Press DEC (decrease) switch (6), and decrease GAIN by one count.
5.
Press PRESET switch (3).
6.
Press IDLE switch (2) to exit program.
END OF TASK
PRESSURE GOVERNOR SENSITIVITY ADJUSTMENT
1.
With MODE displayed in MESSAGE CENTER (1), press and hold IDLE switch (2) and PRESET switch (3),
and press MODE switch (4).
2.
Release IDLE switch (2) and PRESET switch (3), and press MODE switch (4) until SENSITIVITY is displayed
in MESSAGE CENTER (1).
3.
Press INC (increase) switch (5) to select SENSITIVITY.
NOTE
Adjustments to pressure governor controls should be made in small increments.
Note value of SENSITIVITY.
4.
Using INC (increase) switch (5), increase SENSITIVITY by one count.
5.
Press PRESET switch (3).
6.
Press IDLE switch (2) to exit program.
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-


Back to Top