TM 5-4210-249-13&P-3
0407-1
DRAFT
0407
FIELD LEVEL MAINTENANCE
POWER DISTRIBUTION BOX (PUMP HOUSE) REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Remove four nuts (1), lockwashers (2), eight washers (3), four screws (4), and power distribution box (5) from
bracket (6).
Discard lockwashers.
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT2522
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Lockwasher (4)
References
WP 0615, Fig. 83
Equipment Conditions
Pump house panel S removed (WP 0540)
Preheat breaker removed (WP 0391)
Auto fill control removed (WP 0363)
Power distribution box control panel (pump
house) removed (WP 0408)
Terminal block (pass-through)
removed (WP 0429)
Dual governor pressure switch
removed (WP 0392)