TM 5-4210-249-13&P-3
0416-1
DRAFT
0416
FIELD LEVEL MAINTENANCE
PUMP HOUSE COOLING FAN REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.
Disconnect connector (1).
2.
Remove four locknuts (2), eight washers (3), four screws (4), clips (5), and pump house cooling fan (6) from
pump house panel A (7).
Discard locknuts.
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00918
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Locknut (4)
References
WP 0615, Fig. 80
Equipment Conditions
Pump house panel A opened (WP 0539)