TM 5-4210-249-13&P-3
0415-1
DRAFT
0415
FIELD LEVEL MAINTENANCE
PUMP HOUSE HEATER DIAGNOSTIC MODULE REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Remove cable ties as required.
Tag and mark wires prior to removal to ensure proper installation.
1.
Disconnect heater diagnostic module connector (1) from pump house wire harness connector (2).
NOTE
Note position of washers prior to removal to ensure proper installation.
2.
Remove two screws (3), box (4), and two washers (5) from frame rail (6).
3.
Remove data plate (7) from box (4) (WP 0518).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT04651
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Compound, Sealing (WP 0625, Item 17)
Tags, Identification (WP 0625, Item 51)
Ties, Cable, Plastic (WP 0625, Item 58)
Lockwasher (1)
Locknut (1)
Locknut (2)
Materials/Parts
Locknut (2)
Lockwasher (2)
References
WP 0518
WP 0615, Fig. 173
Equipment Conditions
Batteries disconnected (TM 9-2320-325-14&P)
Pump house panel A opened (WP 0539)