TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 786 of 1488

TM 5-4210-249-13&P-3
0457-6
DRAFT
0457
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8.
Connect pump house wire harness connector (11) on pump house power distribution wire harness connector
DP1 (12).
9.
Connect pump house wire harness connector (9) on pump house power distribution wire harness connector
DP2 (10).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10. Install five wires 1138 (7) on pass-through terminal block (8) with lockwasher (6) and nut (5).
11. Install wire 1640 (3) on pass-through terminal block (4) with lockwasher (2) and nut (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Install pump house panel S (WP 0540)
END OF TASK
END OF WORK PACKAGE
TFFT03056
TFFT03055


Back to Top