TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 865 of 1488

TM 5-4210-249-13&P-3
0463-5
DRAFT
0463
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Connection to main wire harness is on front, center of crew cab.
Access and visibility
limited.
18. Disconnect valve control wire harness connector (35) from main wire harness connector (36).
19. Remove valve control wire harness (37) from vehicle.
END OF TASK
INSTALLATION
NOTE
Install diodes as noted prior to removal.
Install cable ties, looms, and cushion clips as noted.
Route wire harness as noted prior to removal.
1.
Connect valve control wire harness connector (35) to main wire harness connector (36).
2.
Install diode (33) on valve control wire harness connector (34).
3.
Install diode (31) on valve control wire harness connector (32).
4.
Connect auto tank fill valve control connector (29) to valve control wire harness connector (30).
TFFT03119


Back to Top