TM-5-4210-249-13-P-4

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 4 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-4 - Page 171 of 1012

TM 5-4210-249-13&P-4
0584-1
DRAFT
0584
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR COMPENSATOR REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Position suitable container under vehicle to catch excess hydraulic oil.
1.
Remove hose (1) from elbow (2).
2.
Remove four screws (3), three preformed packings (4), and hydraulic generator compensator (5) from PTO
pump (6).
Discard preformed packings.
3.
Remove elbow (2) from hydraulic generator compensator (5).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00608
Tools and Special Tools
Drain Pan (WP 0622, Item 9)
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Oil, Lubricating (WP 0625, Item 38)
Preformed Packing (3)
References
WP 0615, Fig. 179
Equipment Conditions
Hydraulic reservoir drained (WP 0588)
Pump house panel G removed (WP 0540)


Back to Top