TM-5-4210-249-13-P-4

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 4 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-4 - Page 281 of 1012

TM 5-4210-249-13&P-4
0607-1
DRAFT
0607
FIELD LEVEL MAINTENANCE
PLUMBING INSULATION REPLACEMENT
INITIAL SETUP:
REMOVAL
CAUTION
Do not cut heat tape when removing insulation from plumbing.
Damage to
electrical wires in heat tape may occur.
NOTE
If reusing original insulation, do not cut along glued seam when cutting insulation off of
plumbing.
Use a very sharp long blade knife to cut insulation.
Make long strokes with knife for best results.
The cut must be clean and not ragged for best results when gluing back together.
1.
Cut insulation (1) with knife.
2.
Remove insulation (1) from plumbing (2).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00675
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Adhesive, Armacell 520 (WP 0625, Item 1)
Insulation, Armacell, Armaflex
(WP 0625, Item 29)
Equipment Conditions
Water pump engine OFF (WP 0022)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)


Back to Top