TM-5-5420-202-20-1

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 1 OF 4

OCTOBER 1985

  TM-5-5420-202-20-1 - Page 648 of 1020

Change 6
4-414.27
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
TM 5-5420-202-20-1
First Technician (Commander’s Station)
Connect red probe of meter to pin D of harness
12326542 that was removed from accessory
relay.
Connect black probe of meter to "T" harness
socket C.
Check if meter indicates continuity.
Check ground wire from voltage regulator in
harness 12326542 for continuity.
Does meter indicate continuity?
56
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
Replace harness 12326542 (page
10-1).
NO
57
YES
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
Connect harness 12326542
connector (1, 1A, 532, 533, 534)
to voltage regulator.
Replace accessory relay (page
10-1).
58
12326542


Back to Top