Change 6
4-414.27
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
TM 5-5420-202-20-1
First Technician (Commander’s Station)
•
Connect red probe of meter to pin D of harness
12326542 that was removed from accessory
relay.
•
Connect black probe of meter to "T" harness
socket C.
•
Check if meter indicates continuity.
Check ground wire from voltage regulator in
harness 12326542 for continuity.
Does meter indicate continuity?
56
•
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
•
Replace harness 12326542 (page
10-1).
NO
57
YES
•
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
•
Connect harness 12326542
connector (1, 1A, 532, 533, 534)
to voltage regulator.
•
Replace accessory relay (page
10-1).
58
12326542