TM-5-5420-202-20-1

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 1 OF 4

OCTOBER 1985

  TM-5-5420-202-20-1 - Page 649 of 1020

4-414.28
Change 6
TM 5-5420-202-20-1
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
Second Technician (Operator’s Station)
Set MASTER BATTERY switch OFF.
Disconnect harness 12326536 (1A, 76, 54A,
459A, 486) from master control panel.
Connect black probe of meter to 12326536
(1A, 76, 54A, 459A, 486) pin D.
First Technician (Commander’s Station)
Connect red probe of meter to “T” harness
socket A.
Check if meter indicates continuity.
Check CKT 1A from connector at voltage
regulator to connector at master control panel.
Does meter indicate continuity?
59
NO
YES
FROM STEP 5
Check CKT 1A from connector
at disconnect panel to
connector at master control
See step 66.
60
12326536 (1A, 76, 54A, 459A, 486)


Back to Top