TM-5-5420-202-20-1

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 1 OF 4

OCTOBER 1985

  TM-5-5420-202-20-1 - Page 652 of 1020

Change 6
4-415
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
TM 5-5420-202-20-1
NO
First Technician (Commander’s Station)
Disconnect harness 12326536 (1A, 76, 54A,
459A, 486) from disconnect plate.
Connect red probe of meter to 12326536 (1A,
76, 54A, 459A, 486) pin D.
Second Technician (Operator’s Station)
Connect black probe of meter to 12326536
(1A, 76, 54A, 459A, 486) pin D.
Check if meter indicates continuity.
Check CKT 1A from connector at disconnect
plate to connector at master control panel.
Does meter indicate continuity?
66
Replace harness 12326536 (1A,
76, 54A, 459A, 486) (page 10-1).
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
Disconnect “T” harness from
voltage regulator.
Connect harness 12326542
connector (1, 1A, 532, 533, 534)
to voltage regulator.
Replace commander’s floor plate
(page 17-9).
67
YES
Disconnect “T” harness from
harness 12326542 connector
(1, 1A, 532, 533, 534)
.
Disconnect “T” harness from
voltage regulator.
Replace harness 12326542
(page 10-1).
Connect harness 12326536
(1A, 76, 54A, 459A, 486) to
disconnect plate.
Connect harness 12326536
(1A, 76, 54A, 459A, 486) to
master control panel.
68
FROM STEP 60
12326536 (1A, 76, 54A, 459A, 486)
12326536 (1A, 76, 54A, 459A, 486)


Back to Top