TM-5-5420-202-20-2

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 2 OF 4

OCTOBER 1985

  TM-5-5420-202-20-2 - Page 361 of 734

TM 5-5420-202-20-2
SERVICE DUST DETECTOR FILTER STRIP (Sheet 1 of 2)
SUPPLIES:
Pipe cleaner (Item 75, Appendix D)
Tubing, non-metallic (Item 78, Appendix D)
Wire, 0.030 inch diameter (Item 63, Appendix D)
Cloth (Item 12, Appendix D)
Dry cleaning solvent (Item 55, Appendix D)
Goggles (Item 70, Appendix D)
Rubber gloves (Item 69, Appendix D)
PRELIMINARY PROCEDURE:
Remove dust detector filter strip and cover (page 7-130.11)
SERVICE:
1.
2.
3.
Dry cleaning solvent P-D-680 is
toxic and flammable.
Wear pro-
tective goggles and gloves and use
only in a well-ventilated area.
Avoid contact with skin, eyes, and
clothes and don’t breathe vapors.
Do not use near open flame or
excessive heat. The flash point for
Type #1 Dry Cleaning Solvent is
100°F (38°C) and for Type #2 is
138°F (50°C). If you become dizzy
while using cleaning solvent, get
fresh air immediately and get
medical aid. If contact with eyes
is made, wash your eyes with water
and get medical aid immediately.
Using clean cloth dampened with cleaning
solvent , clean cover (A) and mount-
ing face of compressor housing (B).
Inspect compressor housing chamber (C)
for contamination. Clean chamber (C) as
required.
Using pipe cleaner clean compressor
housing orifice chamber (C). Use wire
to clean orifice (D). Blow out chamber
(C) and orifice (D) by mouth, using a short
piece of tubing.
Go on to Sheet 2
7-130.14
Change 1


Back to Top