TM-5-5420-202-20-2

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 2 OF 4

OCTOBER 1985

  TM-5-5420-202-20-2 - Page 524 of 734

TM 5-5420-202-20-2
MANIFOLD HEATER OPERATIONAL CHECK (Sheet 2 of 2)
3.
4.
5.
6.
7.
8.
9.
At driver’s station on master control panel (B) set FUEL PUMPS switch (C) to OFF (down)
and MASTER BATTERY switch (D) to ON (up).
Press STARTER BUTTON (E) and at same time operate purge pump handle (F) while pressing
heater button (G) on end of handle.
Check system for leaks. Correct as necessary. When no leaks are present continue with
step 4 and 6.
Check that heater is operating. Heat will be felt at intake manifold heater tube (A).
If no heat is felt, troubleshoot and correct (page 4-1).
When checks are complete, stop operating purge pump handle (F). Hold ENGINE FUEL
SHUTOFF switch (H) to OFF. Set MASTER BATTERY swtich to OFF (down).
Disconnect engine from powerplant test run hookup (page 5-40).
Install powerplant (page 5-14).
End of Task
7-289


Back to Top